How long will a power station run a CPAP?
The useful number is nights, not watt-hours. Below is that number for all 26 models in the database, at three realistic settings — because the humidifier and the inverter between them decide most of the answer.
What a CPAP actually draws
A full-size machine at a typical pressure of 7–12 cmH₂O draws 30–60W with the humidifier off. Turn on the heated humidifier and the heated tube and that climbs to 70–100W, because both are heating elements and a heating element does not get efficient. Travel machines like the AirMini sit at 5–20W, but they have no traditional humidifier to feed.
Pressure matters less than people expect, and leaks matter more: a mask leaking badly makes the blower work harder all night. The figures below use 40W for a machine with the humidifier off and 85W with it on — the middle of each published range.
Nights of backup, all 26 models
Nights of 8 hours. The DC column assumes a 12V cord straight from the station's car socket; the AC columns go through the inverter.
| Model | Capacity | No humidifier, 12V DC | No humidifier, AC outlet | Humidifier + heated tube, AC |
|---|---|---|---|---|
| EcoFlow RIVER 3 | 245 Wh | 0.7 | 0.6 | 0.3 |
| EcoFlow RIVER 2 | 256 Wh | 0.7 | 0.6 | 0.3 |
| Bluetti EB3A | 268 Wh | 0.7 | 0.7 | 0.3 |
| Anker SOLIX C300 | 288 Wh | 0.8 | 0.7 | 0.3 |
| Jackery Explorer 300 | 293 Wh | 0.8 | 0.7 | 0.3 |
| Goal Zero Yeti 500X | 505 Wh | 1.4 | 1.3 | 0.6 |
| EcoFlow RIVER 2 Max | 512 Wh | 1.5 | 1.3 | 0.6 |
| Bluetti EB70S | 716 Wh | 2.1 | 1.9 | 0.8 |
| EcoFlow RIVER 2 Pro | 768 Wh | 2.2 | 2.0 | 0.9 |
| Bluetti AC70 | 768 Wh | 2.2 | 2.0 | 0.9 |
| EcoFlow DELTA 2 | 1,024 Wh | 3.0 | 2.7 | 1.2 |
| EcoFlow DELTA 3 Plus | 1,024 Wh | 3.0 | 2.7 | 1.2 |
| DJI Power 1000 | 1,024 Wh | 3.0 | 2.7 | 1.2 |
| Anker SOLIX C1000 | 1,056 Wh | 3.1 | 2.8 | 1.3 |
| Jackery Explorer 1000 v2 | 1,070 Wh | 3.1 | 2.8 | 1.3 |
| Bluetti AC180 | 1,152 Wh | 3.4 | 3.0 | 1.4 |
| Goal Zero Yeti 1500X | 1,516 Wh | 4.5 | 4.0 | 1.8 |
| Jackery Explorer 2000 Plus | 2,042 Wh | 6.0 | 5.4 | 2.5 |
| EcoFlow DELTA 2 Max | 2,048 Wh | 6.0 | 5.4 | 2.5 |
| Bluetti AC200L | 2,048 Wh | 6.0 | 5.4 | 2.5 |
| Anker SOLIX F2000 (767) | 2,048 Wh | 6.0 | 5.4 | 2.5 |
| Bluetti Elite 200 V2 | 2,073 Wh | 6.1 | 5.5 | 2.5 |
| Jackery Explorer 3000 Pro | 3,024 Wh | 8.9 | 8.0 | 3.7 |
| EcoFlow DELTA Pro | 3,600 Wh | 10 | 9.5 | 4.5 |
| Anker SOLIX F3800 | 3,840 Wh | 11 | 10 | 4.8 |
| EcoFlow DELTA Pro 3 | 4,096 Wh | 12 | 10 | 5.1 |
What size you actually need
Read this as a floor, not a recommendation: it is the smallest pack in the database that clears each threshold, with nothing left over for a phone, a lamp or a cold night.
| If you want | Smallest model that covers it | Capacity |
|---|---|---|
| One night, humidifier on | EcoFlow DELTA 2 | 1,024 Wh |
| Two nights, humidifier on | Jackery Explorer 2000 Plus | 2,042 Wh |
| Three nights, humidifier on | Jackery Explorer 3000 Pro | 3,024 Wh |
| Two nights, humidifier off | EcoFlow RIVER 2 Pro | 768 Wh |
| Four nights, humidifier off | Goal Zero Yeti 1500X | 1,516 Wh |
Cheapest way to clear one full night with the humidifier running: the Jackery Explorer 1000 v2 at $799 launch price ($0.75/Wh), which is not the same model as the smallest one that clears it.
Four things that shorten the night
The humidifier
It is the single biggest variable on this page. Switching it off roughly doubles every number in the last column of the table above.
The inverter, and the station's own idle draw
Running through the AC outlet costs about 15% before the machine sees a watt. On top of that the station itself runs its inverter, display and fans all night; on most units that is a few watts, which over eight hours quietly removes another 20–60Wh from a pack you have already budgeted. The DC column avoids both.
The low-load cutoff
A CPAP is a small load. Several stations interpret "small" as "nothing plugged in" and shut the AC outlet down after a timeout. This is a settings problem, not a capacity problem, and it is the most common way a plan that worked on paper fails at 2am.
Cold
LiFePO4 packs deliver less at low temperatures and most refuse to charge below freezing. For a machine you rely on in a cold room or a van in winter, treat the table above as an optimistic figure.
If the machine stays plugged in at home
For grid outages the useful feature is UPS passthrough: the station sits between the wall and the machine and takes over when the power drops. 14 models here switch in 20 ms or less — EcoFlow DELTA 3 Plus (10 ms), EcoFlow DELTA Pro 3 (10 ms), EcoFlow RIVER 3 (20 ms), Bluetti EB3A (20 ms), Anker SOLIX C300 (20 ms), among others.
How we calculated this
Capacity × efficiency ÷ watts ÷ 8 hours. Efficiency is 85% through the AC inverter and 95% on the DC socket, and the capacity is the manufacturer's rated figure, which is measured at the cells rather than at the outlet. Every number here is therefore an estimate built from published specifications, not something we measured with a meter on a real machine — where a figure would need a measurement to be honest, we say so rather than round it up.